SOLUTIONS

Fire Suppression Systems for Automatic Fire Protection

SYMATEC SECURITY designs and implements Fire Suppression Systems, including gaseous fire suppression, water mist, sprinkler and pre-action sprinkler systems controlled by Integral EvoxX fire suppression control panels. Fire Suppression Systems automatically respond to fire, helping to protect critical technologies, valuable assets and business continuity. Schrack Seconet solutions with Integral EvoxX and Integral C control panels provide reliable control of gaseous suppression, water mist, sprinkler and pre-action sprinkler systems across a wide range of building types and applications.

WHAT ARE FIRE SUPPRESSION SYSTEMS?

Automatic Fire Protection for Buildings and Critical Assets

Fire Suppression Systems are designed to automatically suppress or extinguish a fire at its earliest stage. Once a fire has been detected and verified, the Fire Detection System (FDS) or the Integral EvoxX Fire Suppression Control Panel activates the appropriate extinguishing agent, helping to minimise damage to property, critical technologies and business operations.

Rapid Response

Automatic activation of the suppression system enables immediate intervention as soon as a fire has been confirmed.

Protection of Critical Assets

Fire Suppression Systems are widely used to protect server rooms, data centres, industrial equipment and other mission-critical facilities.

Multiple Suppression Technologies

Depending on the application, systems may use gaseous fire suppression, water mist, sprinkler or pre-action sprinkler technologies.

APPLICATIONS

Solutions for Buildings with High Fire Protection Requirements

Fire Suppression Systems are used wherever it is essential to minimise fire damage, protect critical technologies, maintain business continuity or safeguard high-value assets.

Server Rooms

Automatic fire suppression for facilities with a high concentration of IT equipment and continuous operation.

Energy Facilities

Protection of substations, technical installations and other facilities with demanding safety requirements.

HOW FIRE SUPPRESSION SYSTEMS WORK

Automatic Response from Fire Detection to Fire Suppression

Fire Suppression Systems operate in conjunction with the Fire Detection System (FDS), which detects and verifies a fire event. Once the alarm has been confirmed, the Integral EvoxX Fire Suppression Control Panel coordinates and activates the appropriate suppression system according to the building type and the protected technology.

01

Fire Detection

Schrack Seconet fire detectors or the Fire Detection System (FDS) detect a fire within the protected area.

02

Event Verification

The system verifies the fire event and prepares the activation of the Fire Suppression System.

03

Integral EvoxX Control Panel

The Integral EvoxX Fire Suppression Control Panel coordinates every stage of the suppression process and ensures safe system operation.

04

Suppression System Activation

Depending on the application, the system activates gaseous fire suppression, water mist or a sprinkler system.

05

Fire Suppression

The extinguishing agent suppresses or extinguishes the fire before it can spread further.

SCHRACK SECONET TECHNOLOGIES

Advanced Technologies for Automatic Fire Suppression

Symatec Security uses Schrack Seconet technologies to protect server rooms, data centres, industrial facilities and other buildings with demanding fire protection requirements.

Integral EvoxX

Schrack Seconet Fire Suppression Control Panel designed to coordinate automatic Fire Suppression Systems. Integral EvoxX controls gaseous fire suppression, water mist, sprinkler and pre-action sprinkler systems, including seamless integration with the Fire Detection System (FDS).

Integral C

A dedicated control system for Fire Suppression Systems, designed to coordinate gaseous fire suppression, sprinkler installations and other suppression technologies in industrial and mission-critical facilities.

Gaseous Fire Suppression Systems

Systems using CO₂, inert gases or argon provide effective fire suppression without damaging sensitive equipment. They are ideally suited for server rooms, data centres and other mission-critical technical areas.

Water Mist Systems

Water mist systems generate extremely fine water droplets that efficiently cool the fire and suppress combustion. They provide an effective solution for protecting valuable equipment and high-value assets.

Sprinkler Systems

Automatic sprinkler systems designed to protect warehouses, logistics centres, manufacturing facilities and other buildings with demanding fire protection requirements.

Pre-action Sprinkler Systems

A specialised sprinkler system designed for environments where accidental water discharge must be avoided. Commonly used in data centres, archives and mission-critical technical facilities.

KEY BENEFITS

Why Choose Fire Suppression Systems?

Fire Suppression Systems provide automatic protection for buildings, critical technologies and business operations. Combined with Schrack Seconet technologies, they enable rapid fire response while minimising damage and operational disruption.

Automatic Response

The Fire Suppression System is activated immediately after a fire has been confirmed, helping to prevent further fire spread.

Protection of Sensitive Equipment

Gaseous Fire Suppression Systems using CO₂, argon or inert gases extinguish fires without damaging servers, data storage systems and other sensitive equipment.

Reduced Fire Damage

Water mist systems suppress fires efficiently while using significantly less water than conventional sprinkler systems, reducing secondary damage.

Integration with the Fire Detection System

The Integral EvoxX Fire Suppression Control Panel integrates seamlessly with the Fire Detection System (FDS) and coordinates every stage of the suppression process.

Protection of Critical Facilities

Ideal for server rooms, data centres, power facilities, archives, warehouses and industrial production areas.

High Reliability

Schrack Seconet technologies and the Integral EvoxX Fire Suppression Control Panel provide reliable system supervision, integration with the Fire Detection System and dependable operation throughout the system lifecycle.

DESIGN & IMPLEMENTATION

From Site Assessment to Reliable Fire Protection

Every Fire Suppression System is individually designed to match the characteristics of the building, operational requirements and the type of assets being protected. Our solutions include Integral EvoxX Fire Suppression Control Panels, gaseous fire suppression, water mist, sprinkler and pre-action sprinkler systems, fully integrated with the Fire Detection System (FDS).

01

Site Assessment

Evaluation of fire risks, building operations, protected technologies and fire protection requirements.

02

System Design

Selection of the most appropriate Fire Suppression System, including gaseous fire suppression, water mist, sprinkler or pre-action sprinkler technology.

03

Engineering Design

Preparation of the technical design, including integration with the Fire Detection System (FDS), fire system monitoring and control via the Integral EvoxX Fire Suppression Control Panel.

04

Installation

Installation of pipework, extinguishing agents, control equipment and all other system components.

05

System Configuration

Configuration of the Integral EvoxX Fire Suppression Control Panel, suppression logic and communication with other building systems.

06

System Testing

Verification of Fire Suppression System performance, communication with the Fire Detection System (FDS) and correct activation of all suppression modes.

07

User Training

Training authorised personnel in system operation, alarm procedures and recommended maintenance practices.

SERVICE & MAINTENANCE

Reliable Performance Throughout the Entire System Lifecycle

Fire Suppression Systems require regular inspections, professional servicing and periodic functional testing. Maintenance includes verification of the Integral EvoxX Fire Suppression Control Panel, extinguishing agents, communication with the Fire Detection System (FDS) and all components required for reliable system activation.

Regular Inspections

Inspection of the Fire Suppression System, the Integral EvoxX Fire Suppression Control Panel, alarm functions and integration with the Fire Detection System (FDS).

Functional Testing

Verification of correct suppression system activation, interlocks, alarm signalling and all safety procedures.

System Configuration

Configuration of the Integral EvoxX Fire Suppression Control Panel, suppression logic and interfaces with gaseous fire suppression, water mist and sprinkler systems.

Extinguishing Agent Inspection

Inspection of extinguishing agents, pressure vessels, distribution pipework and overall system readiness for automatic activation.

Technical Support

Fault diagnosis, professional consultancy and technical support for Integral EvoxX Fire Suppression Control Panels, gaseous fire suppression, water mist and sprinkler systems.

Documentation

Maintaining service records, functional test reports, inspection certificates and operational documentation for the Fire Suppression System.

FAQ

Frequently Asked Questions About Fire Suppression Systems

Answers to the most common questions about Fire Suppression Systems, Integral EvoxX Fire Suppression Control Panels, gaseous fire suppression, water mist, sprinkler systems and integration with Fire Detection Systems (FDS).

A Fire Suppression System is an automatic system designed to suppress or extinguish a fire without requiring immediate human intervention. It is activated after a fire alarm has been confirmed and helps minimise damage to property, critical equipment and business operations.

Integral EvoxX and Integral C are fire suppression control panels developed by Schrack Seconet for the management of automatic Fire Suppression Systems. They control gaseous fire suppression, water mist, sprinkler and pre-action sprinkler systems while providing seamless integration with Fire Detection Systems (FDS).

Gaseous fire suppression systems are commonly used in server rooms, data centres, technical facilities and other locations where water could damage equipment or interrupt critical operations. Typical extinguishing agents include CO₂, argon and inert gases.

CO₂, argon, inert gases and water mist are commonly used depending on the specific application and protection requirements.

Water mist systems produce extremely fine water droplets, providing efficient cooling and fire suppression while using significantly less water. Sprinkler systems discharge larger volumes of water and are particularly suitable for warehouses, industrial facilities and other large open spaces.

A pre-action sprinkler system is a specialised sprinkler solution designed for facilities containing high-value assets. Water is released only after the fire has been confirmed, significantly reducing the risk of accidental discharge.

Yes. Fire Suppression Systems can be fully integrated with Fire Detection Systems (FDS). The Integral EvoxX Fire Suppression Control Panel coordinates communication between fire detection and suppression system activation.

Fire Suppression Systems are widely used in server rooms, data centres, manufacturing facilities, logistics centres, energy infrastructure, healthcare facilities and other buildings requiring a high level of fire protection.

Need a Fire Suppression System for Your Building?

Contact SYMATEC SECURITY and we will design a Fire Suppression System tailored to your building and operational requirements. We supply Integral EvoxX systems, gaseous fire suppression, water mist, sprinkler and pre-action sprinkler systems, including integration with the Fire Detection System (FDS).

Contact Us